Twin Datalink Cable

 

Applications :

  • The cables are used as interconnecting cables for Solid State Interlocking (SSI) systems.

Standards :

  • BR 1932
 

 

Construction :

  • Conductors : Class 1 solid plain copper conductor, 1.27mm nominal diameter.
  • Insulation : Solid polyethylene.
  • Inner Sheath : Low density polyethylene.
  • Moisture Barrier : PE Copolymer coated aluminium tape.
  • Sheath : Low density polyethylene.
  • Core Identifi cation : Blue & Red.

Optional :

  • Unarmoured Cable: The cables offered without galvanized steel tapes (SW).
  • Traction Armoured Cable: The cables offered with galvanized steel fl at wire armour with or without protection sheath (SW-F/FT).
  • Halogenfree Sheathed Cable: The cables offered with LSZH sheath according to IEC 60332-3C (SW-CLN/FN).

Electrical Characteristics at 20 °C :

  • Nominal Conductor Diameter mm 1.27
    Nominal Conductor Cross Section mm2 2.5
    Maximum Conductor Resistance Ω/km 7.41

Mechanical and Thermal Properties :

  • Minimum Bending Radius : 6 × OD.
  • Temperature Range : -25°C to +85°C (during operation); -10°C +85°C (during installation).

Dimensions and Weight :

 

Cable Code No. of pairs Nominal Sheath
Thickness
mm
Overall Diameter
Min/Max
mm
Nominal Weight
kg/km
1.27mm Conductor, 2.59mm Insulation Wire
RS1932-2Y2Y(L)2Y-1P1.27 1 2.5 12.47/12.8 136

 

 

UV Resistant
Anti Induction
Water Resistant
Rated Voltage
Buried in Ciround
Laid In conduit
Zero Halogen
IEC 60754-1/NF C20-454
EN 50267-2-1